📖
eVOLVER
  • eVOLVER Documentation Wiki
  • General
    • About Us
    • eVOLVER Community
      • Code of Conduct
  • Getting Started
    • Buying eVOLVER
    • Part Sourcing
    • Unboxing and Setting Up
    • Software Installation
      • DPU Installation
      • Electron App (GUI) Installation
    • Configuring Computer and Networking
      • Router Setup
    • Calibrations
      • Temperature Calibration
      • Optical Density Calibration
      • Pump Calibration
      • Manual Calibration - calibrate.py
  • Upgrade Base eVOLVER Hardware
  • Experiments
    • Starting an Experiment
      • Carboy Media Prep
      • Preparing Vials
      • Setup Waste Carboy
      • Sterilizing Lines
      • Loading Vials and Setting Initial Conditions
      • OD Blank
      • GUI Start Guide
      • Command Line Start Guide
      • Cleaning Up After Experiment
    • Growth Curve
    • Chemostat
    • Turbidostat
    • FAQs
    • Tips and Tricks
  • Guides
    • Use the GUI to Control Parameters
    • Building a Smart Sleeve
    • Making media bottles and splitters
    • Emergency Efflux
    • View the Server Log and Restart Server
    • Updating the eVOLVER Server
    • Change Your conf.yml File
    • Arduino Software Installation
    • Raspberry Pi Configuration
    • Command Line Usage
    • Millifluidics Guides
      • Designing Millifluidics Using Eagle
      • Constructing Laser Cut Millifluidics
      • Constructing Millifluidics via SLA Printing
      • Calibrating IPPs
      • Operating Millifluidics
  • Troubleshooting
    • Troubleshooting Overview
    • Experiment Troubleshooting
      • Contamination
      • Vial Overflow, Pump Failure, and Spills
      • Tubing and Connector Blockage and Bursting
    • Optical Density (OD) Readings
    • Vial Troubleshooting
      • Replacing Photodiodes and LEDs
      • Heating Element
      • Stirring
    • Server Troubleshooting
    • Vial Platform Troubleshooting
      • Motherboard Troubleshooting/Replacement
      • 12V Power Supply Troubleshooting/Replacement
    • GUI Troubleshooting
    • eVOLVER Maintenance
  • Hardware
    • Overview of Hardware Architecture
    • Overview of Fluidics
      • Tubing and connectors
      • Peristaltic Pumps
      • Fluidics box
    • Overview of Millifluidics
      • IPPs (Integrated Peristaltic Pumps)
      • Pressure Regulator
    • Vial Caps
      • Universal Vial Cap Construction Guide (Luer Connectors Only)
      • 5 and 7 Port Nylon Tubing Caps Construction Protocol
    • Smart Sleeve
      • Vial Board
      • 🌪️Stirring
      • Temperature
      • Optical Density
        • OD90 vs OD135
    • Motherboard Layout and Circuitry
      • 🌡️Arduino
      • Sensor/Actuator Board Slots
      • Pulse Width Modulation (PWM) Boards
      • Analog-to-Digital Converter (ADC) Boards
    • Raspberry Pi
    • Chassis
    • Light Blocker / Splash Guard
    • Known Issues
  • Software
    • Overview of Software Architecture
    • DPU
      • Calibration
      • custom_script.py
      • Experiment Data Files
      • eVOLVER.py
    • Arduino
    • Server (Raspberry Pi)
      • Calibration Files
      • Configuration Files (conf.yml)
    • Known Issues
  • Extensions
    • Adding A New Experimental Parameter
      • Power Supply
      • Specific Applications
      • Custom Calibration Code
    • Custom Experiments
      • ePACE
        • ATTiny1634 Writing
        • LUX Board Troubleshooting
      • Morbidostat
      • Extractor Column
        • Extractor Volume Maintenance
        • Experiment Start
          • Sterilizing Extractor Fluidics
          • Setting up your experiment
          • Using the extractor script
        • Extractor Analysis
        • Troubleshooting
        • Example protocols
      • Phototroph Growth
        • Setup Phototroph eVOLVER
        • Photo-eVOLVER Smart Sleeves
          • Photo-eVOLVER Smart Sleeve Construction Guide
        • Experiment Guide
    • Custom Fluidics
      • Adding a Third Pump Rack
      • Bubblers / In-Vial Aeration
        • Bubbler Construction Protocol
        • Bubbler Cleaning Protocol
      • Running the slow pumps
    • min-eVOLVER
      • About
      • min-eVOLVER Construction
        • Parts
        • Construction Protocol
      • Fluidics Setup
      • Software Installation and Startup
      • send_command.py
      • Calibrations
      • Starting an Experiment
      • ePACE with min-eVOLVER
        • [v1.1] ePACE with min-eVOLVER
      • Troubleshooting
    • Interfacing with Other Systems
  • Contributing
    • Guidelines for Contribution
    • Reporting a Bug / Hardware Failure
    • Documentation
      • Making a Forum Post
      • How to Edit the Wiki
    • Software Development
    • Hardware Development
Powered by GitBook
On this page
  • Base eVOLVER Requirements
  • Phototroph eVOLVER Hardware Setup
  • OD Considerations
  • Additional Calibration Procedures

Was this helpful?

Edit on GitHub
Export as PDF
  1. Extensions
  2. Custom Experiments
  3. Phototroph Growth

Setup Phototroph eVOLVER

PreviousPhototroph GrowthNextPhoto-eVOLVER Smart Sleeves

Last updated 1 month ago

Was this helpful?

Base eVOLVER Requirements

  1. From :

    1. eVOLVER base

    2. Fluidics box

    3. 2X fast pump racks

    4. [Optional] Additional slow pump rack for inducers

  2. Dedicated computer for experimentation

    1. Mac strongly recommended for ease of setup and reliability

Phototroph eVOLVER Hardware Setup

The following are different from the base eVOLVER :

  1. Additional fluidics

    1. Bubbling 1-16 millifluidic splitter

    2. Gas mixer (or tank of premixed gas with regulators)

  2. Vials (recommended to get parts for at least two sets)

    1. (plugs in to cap)

    2. Long thin stir bars - required otherwise bubbles will stick and throw off OD readings

  3. Bubbler cleaning apparatus (recommended for saving time)

  4. Light meter and probe

    1. Our light meter is the LI-COR

    2. Our light probe is the Walz US-SQS/L omnidirectional light

OD Considerations

We pause stirring and phototroph growth lights when we take OD. Without this, OD would be nonfunctional. Stirring causes bubbles be pulled downwards and the growth lights completely saturate the OD sensor.

Additional Calibration Procedures

  1. Switch to calibration conf.yml before doing calibration

    1. Because this will give us data every 20 seconds and greatly speed up calibration

  2. Settings during calibration should mimic the experiment therefore:

    1. Phototroph growth lights off

    2. Stirring off

  3. Vial setup for calibration (also mimic the experiment)

    1. Prepare standards in caps with a bubbler

    2. Use long stir bars

  4. When moving standards, give a swirl once every other time

    1. This is to make sure cells don’t settle and change the OD

  5. Finally, switch back to experiment conf.yml when ready for experiment

Fynch Bio
Router
setup
Smart sleeve construction
Emergency efflux
5-port nylon tube cap
Bubbler
LI-1500
probe