📖
eVOLVER
  • eVOLVER Documentation Wiki
  • General
    • About Us
    • eVOLVER Community
      • Code of Conduct
  • Getting Started
    • Buying eVOLVER
    • Part Sourcing
    • Unboxing and Setting Up
    • Software Installation
      • DPU Installation
      • Electron App (GUI) Installation
    • Configuring Computer and Networking
      • Router Setup
    • Calibrations
      • Temperature Calibration
      • Optical Density Calibration
      • Pump Calibration
      • Manual Calibration - calibrate.py
  • Upgrade Base eVOLVER Hardware
  • Experiments
    • Starting an Experiment
      • Carboy Media Prep
      • Preparing Vials
      • Setup Waste Carboy
      • Sterilizing Lines
      • Loading Vials and Setting Initial Conditions
      • OD Blank
      • GUI Start Guide
      • Command Line Start Guide
      • Cleaning Up After Experiment
    • Growth Curve
    • Chemostat
    • Turbidostat
    • FAQs
    • Tips and Tricks
  • Guides
    • Use the GUI to Control Parameters
    • Building a Smart Sleeve
    • Making media bottles and splitters
    • Emergency Efflux
    • View the Server Log and Restart Server
    • Updating the eVOLVER Server
    • Change Your conf.yml File
    • Arduino Software Installation
    • Raspberry Pi Configuration
    • Command Line Usage
    • Millifluidics Guides
      • Designing Millifluidics Using Eagle
      • Constructing Laser Cut Millifluidics
      • Constructing Millifluidics via SLA Printing
      • Calibrating IPPs
      • Operating Millifluidics
  • Troubleshooting
    • Troubleshooting Overview
    • Experiment Troubleshooting
      • Contamination
      • Vial Overflow, Pump Failure, and Spills
      • Tubing and Connector Blockage and Bursting
    • Optical Density (OD) Readings
    • Vial Troubleshooting
      • Replacing Photodiodes and LEDs
      • Heating Element
      • Stirring
    • Server Troubleshooting
    • Vial Platform Troubleshooting
      • Motherboard Troubleshooting/Replacement
      • 12V Power Supply Troubleshooting/Replacement
    • GUI Troubleshooting
    • eVOLVER Maintenance
  • Hardware
    • Overview of Hardware Architecture
    • Overview of Fluidics
      • Tubing and connectors
      • Peristaltic Pumps
      • Fluidics box
    • Overview of Millifluidics
      • IPPs (Integrated Peristaltic Pumps)
      • Pressure Regulator
    • Vial Caps
      • Universal Vial Cap Construction Guide (Luer Connectors Only)
      • 5 and 7 Port Nylon Tubing Caps Construction Protocol
    • Smart Sleeve
      • Vial Board
      • 🌪️Stirring
      • Temperature
      • Optical Density
        • OD90 vs OD135
    • Motherboard Layout and Circuitry
      • 🌡️Arduino
      • Sensor/Actuator Board Slots
      • Pulse Width Modulation (PWM) Boards
      • Analog-to-Digital Converter (ADC) Boards
    • Raspberry Pi
    • Chassis
    • Light Blocker / Splash Guard
    • Known Issues
  • Software
    • Overview of Software Architecture
    • DPU
      • Calibration
      • custom_script.py
      • Experiment Data Files
      • eVOLVER.py
    • Arduino
    • Server (Raspberry Pi)
      • Calibration Files
      • Configuration Files (conf.yml)
    • Known Issues
  • Extensions
    • Adding A New Experimental Parameter
      • Power Supply
      • Specific Applications
      • Custom Calibration Code
    • Custom Experiments
      • ePACE
        • ATTiny1634 Writing
        • LUX Board Troubleshooting
      • Morbidostat
      • Extractor Column
        • Extractor Volume Maintenance
        • Experiment Start
          • Sterilizing Extractor Fluidics
          • Setting up your experiment
          • Using the extractor script
        • Extractor Analysis
        • Troubleshooting
        • Example protocols
      • Phototroph Growth
        • Setup Phototroph eVOLVER
        • Photo-eVOLVER Smart Sleeves
          • Photo-eVOLVER Smart Sleeve Construction Guide
        • Experiment Guide
    • Custom Fluidics
      • Adding a Third Pump Rack
      • Bubblers / In-Vial Aeration
        • Bubbler Construction Protocol
        • Bubbler Cleaning Protocol
      • Running the slow pumps
    • min-eVOLVER
      • About
      • min-eVOLVER Construction
        • Parts
        • Construction Protocol
      • Fluidics Setup
      • Software Installation and Startup
      • send_command.py
      • Calibrations
      • Starting an Experiment
      • ePACE with min-eVOLVER
        • [v1.1] ePACE with min-eVOLVER
      • Troubleshooting
    • Interfacing with Other Systems
  • Contributing
    • Guidelines for Contribution
    • Reporting a Bug / Hardware Failure
    • Documentation
      • Making a Forum Post
      • How to Edit the Wiki
    • Software Development
    • Hardware Development
Powered by GitBook
On this page
  • Stopping Experiment and Bleaching
  • Clean Vials After Bleaching Cultures

Was this helpful?

Edit on GitHub
Export as PDF
  1. Experiments
  2. Starting an Experiment

Cleaning Up After Experiment

PreviousCommand Line Start GuideNextGrowth Curve

Last updated 2 years ago

Was this helpful?

Bleach (sodium hypochlorite) may create a small amount of chloroform when mixed with ethanol. In addition, many EHS policies prohibit mixing of ethanol and bleach waste streams. Considering this, you may want to move your efflux lines to a separate waste container when sterilizing tubing with ethanol, and move them back to your normal waste container when starting your experiment. Also consider using alternative sterilization agents such as and detergent.

Stopping Experiment and Bleaching

  1. In the GUI electron app or command line, click to stop your experiment.

  2. In large beakers, prepare 500mL of 10% bleach and 200 mL of 10% bleach.

  3. Disconnect media bottles and place lines into 10% bleach solution

  4. To use pumps to bleach the cultures, keep tubing connected, but move vials to a white eVOLVER rack. Prepare an additional 1L of 10% bleach and add to the media input beaker.

  5. Run 10% bleach through vials until final concentration in the vials reaches ~10% bleach (~60 seconds for 25mL volume). Disconnect influx and efflux lines from vials, set vials aside for 30 mins.

  6. To manually clean vials, disconnect influx and efflux lines and skip steps 39 and 40

  7. Submerge the disconnected influx and efflux lines in the 200mL bleach beaker, then run all pumps for 20 seconds to fill all lines with 10% bleach. Let sit for no less than 30 minutes, no more than 48 hours.

  8. Remove media input lines from bleach, and run air though the lines to remove bleach. If not planning on using the device again right away, run diH2O through all lines for 20 seconds to remove residual bleach from the lines. Dried bleach can form salt crystals and clog the lines. If this happens, break up the crystals manually using pliers to squeeze the line.

  9. Turn off the 12V power, then the 5V power.

  10. Proceed to vial & bottle cleaning protocol.

Clean Vials After Bleaching Cultures

  1. Prepare a beaker ~50% full of 10% bleach

  2. Remove vial lids and place in 10% bleach solution

  3. Using the magnetic stir bar grabber, remove the stir bars from each vial, place in the 10% bleach solution

  4. Let vial caps and stir bars sit for 30 minutes-overnight in the 10% bleach solution

  5. Meanwhile, dump bleached culture down the drain, rinse with diH2O

  6. Use a test tube brush to scrub inside of vial, particularly important if you grew bacterial cultures

  7. Place bleached/scrubbed vials right-side-up in the vial racks to indicate they have not yet been dishwashed

  8. Once vial lids/stir bars have been soaked for sufficient time, carefully pour out the 10% bleach solution, and replace with diH2O

  9. Let vial lids and stir bars soak for another 30 mins-overnight.

  10. Once vial lids/stir bars have been soaked for sufficient time, carefully pour out the diH2O.

  11. Run diH2O through influx and efflux straws for 2-3 seconds at the sink to remove any residual bleach

  12. Place stir bars in the stir bar tray.

  13. Once 60+ vials have accumulated, vials should be dishwashed.

  14. Place vials open side up in 3 white eVOLVER racks.

  15. Take one rack, cover the vials using the wire mesh from the bottom rack of the dishwasher, then flip upside down. Repeat for the other two racks.

  16. Add any other glassware or eVOLVER bottles to the top rack as desired, then run on cycle 3.

  17. Store vials upside down in vial boxes to indicate that they have been dishwashed.

Wescodyne
BacDown