eVOLVER
  • eVOLVER Documentation Wiki
  • General
    • About Us
    • eVOLVER Community
      • Code of Conduct
  • Getting Started
    • Buying eVOLVER
    • Part Sourcing
    • Unboxing and Setting Up
    • Software Installation
      • DPU Installation
      • Electron App (GUI) Installation
    • Configuring Computer and Networking
      • Router Setup
    • Calibrations
      • Temperature Calibration
      • Optical Density Calibration
      • Pump Calibration
      • Manual Calibration - calibrate.py
  • Upgrade Base eVOLVER Hardware
  • Experiments
    • Starting an Experiment
      • Carboy Media Prep
      • Preparing Vials
      • Setup Waste Carboy
      • Sterilizing Lines
      • Loading Vials and Setting Initial Conditions
      • OD Blank
      • GUI Start Guide
      • Command Line Start Guide
      • Cleaning Up After Experiment
    • Growth Curve
    • Chemostat
    • Turbidostat
    • FAQs
    • Tips and Tricks
  • Guides
    • Use the GUI to Control Parameters
    • Building a Smart Sleeve
    • Making media bottles and splitters
    • Emergency Efflux
    • View the Server Log and Restart Server
    • Updating the eVOLVER Server
    • Change Your conf.yml File
    • Arduino Software Installation
    • Raspberry Pi Configuration
    • Command Line Usage
    • Millifluidics Guides
      • Designing Millifluidics Using Eagle
      • Constructing Laser Cut Millifluidics
      • Constructing Millifluidics via SLA Printing
      • Calibrating IPPs
      • Operating Millifluidics
  • Troubleshooting
    • Troubleshooting Overview
    • Experiment Troubleshooting
      • Contamination
      • Vial Overflow, Pump Failure, and Spills
      • Tubing and Connector Blockage and Bursting
    • Optical Density (OD) Readings
    • Vial Troubleshooting
      • Replacing Photodiodes and LEDs
      • Heating Element
      • Stirring
    • Server Troubleshooting
    • Vial Platform Troubleshooting
      • Motherboard Troubleshooting/Replacement
      • 12V Power Supply Troubleshooting/Replacement
    • GUI Troubleshooting
    • eVOLVER Maintenance
  • Hardware
    • Overview of Hardware Architecture
    • Overview of Fluidics
      • Tubing and connectors
      • Peristaltic Pumps
      • Fluidics box
    • Overview of Millifluidics
      • IPPs (Integrated Peristaltic Pumps)
      • Pressure Regulator
    • Vial Caps
      • Universal Vial Cap Construction Guide (Luer Connectors Only)
      • 5 and 7 Port Nylon Tubing Caps Construction Protocol
    • Smart Sleeve
      • Vial Board
      • 🌪️Stirring
      • Temperature
      • Optical Density
        • OD90 vs OD135
    • Motherboard Layout and Circuitry
      • 🌡️Arduino
      • Sensor/Actuator Board Slots
      • Pulse Width Modulation (PWM) Boards
      • Analog-to-Digital Converter (ADC) Boards
      • RS485 Board
    • Raspberry Pi
    • Chassis
    • Light Blocker / Splash Guard
    • Known Issues
  • Software
    • Overview of Software Architecture
    • DPU
      • Calibration
      • custom_script.py
      • Experiment Data Files
      • eVOLVER.py
    • Arduino
    • Server (Raspberry Pi)
      • Calibration Files
      • Configuration Files (conf.yml)
    • Known Issues
  • Extensions
    • Adding A New Experimental Parameter
      • Power Supply
      • Specific Applications
      • Custom Calibration Code
    • Custom Experiments
      • ePACE
        • ATTiny1634 Writing
        • LUX Board Troubleshooting
      • Morbidostat
      • Extractor Column
        • Extractor Volume Maintenance
        • Experiment Start
          • Sterilizing Extractor Fluidics
          • Setting up your experiment
          • Using the extractor script
        • Extractor Analysis
        • Troubleshooting
        • Example protocols
      • Phototroph Growth
        • Setup Phototroph eVOLVER
        • Photo-eVOLVER Smart Sleeves
          • Photo-eVOLVER Smart Sleeve Construction Guide
        • Experiment Guide
    • Custom Fluidics
      • Adding a Third Pump Rack
      • Bubblers / In-Vial Aeration
        • Bubbler Construction Protocol
        • Bubbler Cleaning Protocol
      • Running the slow pumps
    • min-eVOLVER
      • About
      • min-eVOLVER Construction
        • Parts
        • Construction Protocol
      • Fluidics Setup
      • Software Installation and Startup
      • send_command.py
      • Calibrations
      • Starting an Experiment
      • ePACE with min-eVOLVER
        • [v1.1] ePACE with min-eVOLVER
      • Troubleshooting
    • Interfacing with Other Systems
  • Contributing
    • Guidelines for Contribution
    • Reporting a Bug / Hardware Failure
    • Documentation
      • Making a Forum Post
      • How to Edit the Wiki
    • Software Development
    • Hardware Development
Powered by GitBook
On this page

Was this helpful?

Edit on GitHub
Export as PDF
  1. Extensions
  2. Custom Experiments
  3. Extractor Column

Troubleshooting

Possible errors you can run into

PreviousExtractor AnalysisNextExample protocols

Last updated 4 months ago

Was this helpful?

The main result of issues with the extractor can lead to extractor or non-extractor vials to being empty or result in overflow.

Some factors that can contribute to this are:

Condensation:

Condensation can occur in the extractor vials depending on ambient conditions in the extractor as well as what organism you are working with. Condensation can obscure the photodiodes tricking them into thinking the vial has more volume then it actually does, triggering unwanted pump events. Generally the best solution for this is to ensure the heat is properly working or to raise the temperature of the vial.

Disturbing the experiment:

The extractor and non-extractor vials are delicate when the experiment is actively running. Vials should NOT be moved or sampled while the experiment is actively running. It is recommended to pause the experiment before handling any vials. Moving the extractor vials while the experiment is running can negatively impact the fluidics set up, or move the liquid into range of the photodiodes triggering an unwanted pump event.

Contamination:

Contamination of vials:

Vial contamination will cause a rapid increase in OD which will rapidly accelerate the rate at which pump events occur.

Contamination of media bottle:

If the non-extractor vial begins to overfill if it reaches the main media influx line the inoculated media can work its way back through the line towards your media bottle. Additionally the same can occur if you have your vial-to-vial line dispensing liquid from above your main media influx line which will again expose the main media line to inoculated media.

Improper sterilization of the fluidic lines can also cause contamination

Incorrect Fluidics setup:

Incorrect set up of the fluidics can cause immediate problems during your experiment make sure to double check your setup before starting your experiment

Droplets on side of vial:

In the extractor vials if the straw dripping culture in is placed too high above the liquid level the drops from the straw can splash and cause droplets to collect on the side of the vials. Causing a similar effect to condensation by obscuring the photodiodes triggering unwanted pump events. When designing your extractor caps measure the straw length so it sits at about 1 inch above your desired volume.

Incorrect volume/block setup:

Remember to double check what volume you are putting into the extractor vial, currently the volume of the extractor vials should be no greater than 15 mL the photodiodes should blank "nothing" at both blanking steps extractor vials exceeding 15 mL can interfere with the blanking steps causing immediate problems with pump events. Similarly if using acrylic blocks to elevate extractor vials remember to not account for how much "volume" each block take up.

Dirty vials:

Improperly cleaned vials can run into the same issues as condensation or droplets on the vial, again tricking the photodiodes into triggering an unwanted pump event.

Pair of vials where extractor vial was all pumped out